Open-access In vitro study of the relationship between bond strength to dental enamel and microleakage in photopolymerizable composite resins

Objectives:  To evaluate and compare the relationship between enamel bond strength and microleakage of two composite based restorative systems.

Methods:  40 third molars were randomly divided into two groups: 20 molars restored with the Adper Single bond 2 + Filtek Z250 XT (3M ESPE; ST PAUL, MN, USA) system and 20 with the Tetric N Bond + Tetric N Ceram (Ivoclar Vivadent; Schaan, Liechtenstein) system. Half of the teeth in each group were used for a bond strength test, while the other half were used for the microleakage test.

Results:  The means and standard deviation of the bond strength resistance were 27.93 (± 9.55) MPa for Adper Single bond 2 + Filtek Z250 XT system and 33.12 (± 8.18) MPa for Tetric N Bond + Tetric N Ceram system (p = 0.049). Regarding the microleakage values, there were no statistically significant differences between the groups (p = 0.478). No significant correlation was observed between Microtensile bond strength and microleakage (R2 = 0.0909, p = 0.196).

Conclusions:  It was not found a relationship between adhesive bond values and the degree of microleakage.

Key words:
Bond strength; Microleakage; Composite Resins